CAMAC - 3565
8-channel RTD Signal Conditioner |
View Datasheet
Request
Ordering Information |
|
| |
ABOUT 3565
The Model 3565 is a single-width CAMAC module providing eight channels of
RTD(Resistance Temperature Detector) bridge completion and input filtering as well as
input multiplexing. It is used with the Model 3518 Scanning A/D Converter Host
module.
The 3565 can accommodate RTD transducers of the two-, three-, or four-wiretype.
Each channel of this input module contains the remaining three legs of the bridge for
100 ohm RTDs. If RTDs other than 100 ohms are desired, please contact
KineticSystems Corporation for additional bridge resistor options. In addition, each
channel can be strap-selected for current excitation of four-wire RTDs with resistance
values to 1000 ohms. An excitation source adjustment is provided for each channel. An
on-board calibration resistor may be switched in on a channel-by-channel basis by
means of a calibration relay register. The calibration relay register can be written and
read via the Dataway.
|