CAMAC - 1854/56
Termination Panels |
View Datasheet
Request
Ordering Information |
|
| |
ABOUT 1854/56
The Model 1854 Termination Panel provides a convenient method for field terminating module I/O signals. Arranged for 19-inch relay rack mounting, the panel permits termination of 32 channels of I/O and occupies only 4.45 cm (13/4 inches) of rack
height. The 32 channels are broken into two groups of 16 channels each for mating with modules such as the KSC Models
3512, 3514, and 3516. The Model 1856 is a similar panel with balanced low-pass filters (-3 dB cutoff at 7 kHz) for use with
the Model 4024 Recording Datalogger.
The 1854 panel uses 64 Wago� stainless steel, cage clamp springs to receive the field wiring. Each spring accepts a single
solid or stranded conductor in wire sizes AWG 24 to AWG 14. The springs feature constant contact resistance, are vibration
proof, and are easy to use. Each of these terminals is wired to a contact on a 50-contact (plug) ribbon connector.
|